| Parameters |
| Factory Lead Time |
12 Weeks |
| Mount |
Surface Mount |
| Mounting Type |
Surface Mount |
| Package / Case |
SMD/SMT |
| Number of Pins |
12 |
| Operating Temperature |
-55°C~125°C |
| Packaging |
Tray |
| Published |
2012 |
| Part Status |
Active |
| Moisture Sensitivity Level (MSL) |
4 (72 Hours) |
| Max Operating Temperature |
125°C |
| Min Operating Temperature |
-55°C |
| Diode Type |
PIN |
| Voltage - DC Reverse (Vr) (Max) |
50V |
| Max Reverse Voltage (DC) |
50V |
| Reverse Voltage |
50V |
| Wavelength |
890nm |
| Dark Current |
5μA |
| Spectral Range |
400nm ~ 1100nm |
| Active Area |
0.84mm2 (x6) |
| Current - Dark (Typ) |
5μA |
| Responsivity @ nm |
0.45 A/W @ 890nm |
| Height |
1.52mm |
| Length |
6.73mm |
| Width |
7.24mm |
| RoHS Status |
RoHS Compliant |
OPR2101 Overview
To protect them from damage, these photodiodes are packaged in the Tray. For safety reasons, the photodiodes are packaged in SMD/SMT packages. Continuous reverse-bias means the photodiodes can withstand only 50V voltage. Reverse-bias photodiodes should not be operated above 50V permanently. There are 12 pins on the photodiodes. A photodiode should not operate at a temperature higher than 125°C. However, the photodiodes should be operated at a minimum temperature of -55°C. The photodiodes provided 50V when reverse-biased. The photodiode operates at 5μA current even in the absence of light input.
OPR2101 Features
Moisture Sensitivity Level (MSL): 4 (72 Hours)
Operating Temperature: -55°C~125°C
Packaging: Tray
Diode Type: PIN
Mount: Surface Mount
Spectral Range: 400nm ~ 1100nm
Responsivity @ nm: 0.45 A/W @ 890nm
OPR2101 Applications
There are a lot of TT Electronics/Optek Technology OPR2101 Photodiodes applications.
- Measurement Levelling
- Health Monitoring
- Industrial Automation
- Solar Cells
- Low Capacitance
- Optical Analytics
- Machine Controls
- Diode Laser Monitoring
- Light Bariers
- Range finding