| Parameters | |
|---|---|
| Td (on/off) @ 25°C | 130ns/385ns |
| Switching Energy | 2.6mJ (on), 1.6mJ (off) |
| RoHS Status | ROHS3 Compliant |
| Mounting Type | Through Hole |
| Package / Case | TO-247-3 |
| Supplier Device Package | TO-247 |
| Operating Temperature | -55°C~150°C TJ |
| Packaging | Tube |
| Part Status | Obsolete |
| Moisture Sensitivity Level (MSL) | 3 (168 Hours) |
| Input Type | Standard |
| Power - Max | 260W |
| Reverse Recovery Time | 200ns |
| Voltage - Collector Emitter Breakdown (Max) | 1.2V |
| Current - Collector (Ic) (Max) | 80A |
| Test Condition | 600V, 40A, 10Ohm, 15V |
| Vce(on) (Max) @ Vge, Ic | 2.2V @ 15V, 40A |
| IGBT Type | Trench Field Stop |
| Gate Charge | 415nC |
| Current - Collector Pulsed (Icm) | 160A |