| Parameters |
| Mounting Type |
Surface Mount |
| Package / Case |
8-WDFN Exposed Pad |
| Surface Mount |
YES |
| Operating Temperature |
-40°C~125°C TA |
| Published |
2015 |
| JESD-609 Code |
e3 |
| Pbfree Code |
yes |
| Part Status |
Obsolete |
| Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
| Number of Terminations |
8 |
| ECCN Code |
EAR99 |
| Type |
Regulator/Supervisor |
| Terminal Finish |
Matte Tin (Sn) |
| Additional Feature |
RESET THRESHOLD VOLTAGE IS 2.5V |
| Subcategory |
Power Management Circuits |
| Technology |
BICMOS |
| Terminal Position |
DUAL |
| Terminal Form |
NO LEAD |
| Peak Reflow Temperature (Cel) |
260 |
| Number of Functions |
1 |
| Supply Voltage |
14V |
| Terminal Pitch |
0.65mm |
| Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
| Output |
Open Drain or Open Collector |
| Pin Count |
8 |
| JESD-30 Code |
S-XDSO-N8 |
| Qualification Status |
Not Qualified |
| Supply Voltage-Max (Vsup) |
72V |
| Supply Voltage-Min (Vsup) |
5.5V |
| Number of Channels |
1 |
| Adjustable Threshold |
YES |
| Reset |
Active Low |
| Voltage - Threshold |
2.188V |
| Number of Voltages Monitored |
1 |
| Height Seated (Max) |
0.8mm |
| Length |
3mm |
| Width |
3mm |
| RoHS Status |
ROHS3 Compliant |
MAX6397YATA+ Overview
There are 8 mounting terminals on the voltage supervisor, each of which has a different function. There are 1 functions included in this PMIC so that you can refer to them. Power management consists of 1 channels, each of which can be used independently. In this IC management you will find 8-WDFN Exposed Pad functions for you to refer to. With power management, you get a lot of benefits that you won't find in other Regulator/Supervisor products. The package peak reflow temperature is specified to be 260. In a 14V supply voltage, the power management conducts. A supply voltage of 1 is used to conduct the PMIC chip. There is a subcategory called Power Management Circuits for this power management. It has a total of 8 pins that are attached to IC management. A Surface Mount mounting type is recommended. We recommend setting the supervisors to -40°C~125°C TA degrees. Power management has an output of Open Drain or Open Collector during operation. In addition, IC management are other features such as [0], to mention only a few.
MAX6397YATA+ Features
Regulator/Supervisor type
MAX6397YATA+ Applications
There are a lot of Maxim Integrated MAX6397YATA+ Voltage Supervisors applications.
- Automotive power systems
- DVR
- Precision measurement
- emergency room
- Power distribution systems of ICU
- Transformer load monitoring equipment
- Important electronics for automotive safety
- Data storage applications
- Network equipment
- Detection of phase imbalance