| Parameters | |
|---|---|
| Factory Lead Time | 13 Weeks |
| Mounting Type | Chassis Mount |
| Operating Temperature | 0°C~70°C With Derating |
| Packaging | Bulk |
| Published | 2003 |
| Series | LPT60-M (60W) |
| Size / Dimension | 5.00Lx3.00W x 1.69 H 127.0mmx76.2mmx42.9mm |
| Feature | Adjustable Output, DC Input Capable, Remote Sense, Universal Input |
| Part Status | Active |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| Type | Open Frame |
| Applications | Medical |
| Power (Watts) | 60W 80W Forced Air |
| Power Rating | 60W |
| Number of Outputs | 3 |
| Approval Agency | CE |
| Efficiency | 70% |
| Voltage - Output 1 | 5V |
| Current - Output (Max) | 7A 3A 700mA |
| Voltage - Input | 85V~264VAC |
| Output Power | 60W |
| Voltage - Output 2 | 12V |
| Voltage - Output 3 | -12V |
| Minimum Load Required | Yes |
| RoHS Status | RoHS Compliant |