| Parameters | 
                                
                                                                                                            
                                            | Sensitivity | 
                                            16mV/A | 
                                        
                                                                            
                                            | For Measuring | 
                                            AC/DC | 
                                        
                                                                            
                                            | Current - Sensing | 
                                            50A | 
                                        
                                                                            
                                            | RoHS Status | 
                                            RoHS Compliant | 
                                        
                                                                            
                                            | Factory Lead Time | 
                                            14 Weeks | 
                                        
                                                                            
                                            | Mounting Type | 
                                            Through Hole | 
                                        
                                                                            
                                            | Package / Case | 
                                            Module | 
                                        
                                                                            
                                            | Operating Temperature | 
                                            -40°C~105°C | 
                                        
                                                                            
                                            | Packaging | 
                                            Tray | 
                                        
                                                                            
                                            | Published | 
                                            2014 | 
                                        
                                                                            
                                            | Series | 
                                            HLSR-P | 
                                        
                                                                            
                                            | Part Status | 
                                            Active | 
                                        
                                                                            
                                            | Moisture Sensitivity Level (MSL) | 
                                            Not Applicable | 
                                        
                                                                            
                                            | Voltage - Supply | 
                                            3.3V | 
                                        
                                                                            
                                            | Frequency | 
                                            400kHz | 
                                        
                                                                            
                                            | Output | 
                                            Ratiometric, Voltage | 
                                        
                                                                            
                                            | Current - Supply (Max) | 
                                            25mA | 
                                        
                                                                            
                                            | Number of Channels | 
                                            1 | 
                                        
                                                                            
                                            | Polarization | 
                                            Bidirectional | 
                                        
                                                                            
                                            | Accuracy | 
                                            ±1% | 
                                        
                                                                            
                                            | Response Time | 
                                            2.5μs | 
                                        
                                                                            
                                            | Sensor Type | 
                                            Hall Effect, Open Loop | 
                                        
                                                                            
                                            | Linearity | 
                                            ±0.5% | 
                                        
                                                                                                    
                            
                         
                                                HLSR 50-P/SP33 Overview
A Module package is used to protect the current sensors from damage. Tray protects the current sensors from damage. Current sensors should be capable of providing a maximum current of 25mA. 
HLSR 50-P/SP33 Features
Moisture Sensitivity Level: Not Applicable
Operating Temperature: -40°C~105°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 3.3V
Frequency: 400kHz
Sensing Current: 50A
Module Package
HLSR 50-P/SP33 Applications
There are a lot of LEM USA Inc. HLSR 50-P/SP33 Current Sensors applications. 
- Power factor correction
 - Closed-L oop DC- and AC-Current Sensor Modules
 - General purpose inverters
 - Static converters for DC motor drives
 - Continuity
 - Switched Mode Power Supplies(SMPS)
 - Static converters for for DC motor drives
 - Battery supplied applications
 - Proving Switch
 - Switched Mode Power Supplies (SMPS)