| Parameters |
| Factory Lead Time |
5 Weeks |
| Number of Pins |
4 |
| Housing Material |
Brass |
| Operating Temperature |
-20°C~60°C |
| Packaging |
Bulk |
| Published |
2006 |
| Part Status |
Active |
| Moisture Sensitivity Level (MSL) |
Not Applicable |
| Termination |
Cable |
| Max Operating Temperature |
60°C |
| Min Operating Temperature |
-20°C |
| Voltage - Supply |
10V~40V |
| Ingress Protection |
IP67 |
| Frequency |
100Hz |
| Lead Length |
2m |
| Max Output Current |
200mA |
| Output Configuration |
PNP |
| Cable Length |
78.74 2m |
| Output Current |
200mA |
| Max Voltage Rating (DC) |
40V |
| Turn On Delay Time |
5 ms |
| Response Time |
3.2ms, 5ms |
| Thread Size |
M18 |
| Adjustment Type |
Adjustable, 270° Turn Potentiometer |
| Sensing Distance |
15.748 (400mm) |
| Sensing Method |
Reflective, Diffuse |
| Max Supply Voltage (DC) |
40V |
| Connection Method |
Cable |
| Light Source |
Infrared (880nm) |
| Min Supply Voltage (DC) |
10V |
| REACH SVHC |
No SVHC |
| RoHS Status |
RoHS Compliant |
| Ratings |
IP67 |
EO1804PPAS Overview
It is recommended to set the temperature of a photoelectric sensor to -20°C~60°C in order to ensure reliable operation. For these electronic components to function, a voltage of 10V~40V should be applied to a circuit or system. Photoelectric sensors should have a response time of 3.2ms, 5ms. Ensure reliability by operating the photoelectric sensor at -20°C degrees Celsius or lower. It is possible to operate the system reliably at temperatures up to 60°C. You've got to connect the 4 pins to the photoelectric sensor for it to work. In order for a photoelectric sensor to function, the output current should be 200mA. A photoelectric sensor can be damaged by the maximum DC voltage of 40V. Unlike most photoelectric sensors, this one operates at a very low voltage such as 0 volts. It comes in the package?of a Bulk. Photoelectric sensors can be used with a maximum output current of 200mA. Photoelectric sensors operate with a maximum voltage of 40V in DC circuits.
EO1804PPAS Features
Sensing Distance: 15.748 (400mm)
4 pins
Response Time: 3.2ms, 5ms
Operating Temperature: -20°C~60°C
Maximal Supply Voltage (DC): 40V
Minimal Supply Voltage (DC): 10V
Turn On Delay Time: 5 ms
EO1804PPAS Applications
There are a lot of Carlo Gavazzi Inc. EO1804PPAS Photoelectric Sensors applications.
- Contrast sensors
- Monitoring bigger areas for objects with light grids
- Mechanical engineering
- Luminescence sensors
- Passive infrared sensors
- detect objects
- Counting small objects
- Entrance and gate
- Logistics and materials handling
- Automotive industry