| Parameters |
| Factory Lead Time |
13 Weeks |
| Mount |
PCB |
| Mounting Type |
Through Hole |
| Package / Case |
Module, Single Pass Through |
| Housing Material |
PBT |
| Operating Temperature |
-40°C~85°C |
| Packaging |
Bulk |
| Published |
1998 |
| Series |
CSN |
| Part Status |
Active |
| Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
| Number of Terminations |
3 |
| Voltage - Supply |
±12V~15V |
| Terminal Position |
UNSPECIFIED |
| Peak Reflow Temperature (Cel) |
NOT SPECIFIED |
| Number of Functions |
1 |
| Current Rating |
90A |
| Frequency |
150kHz |
| Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
| Output |
Ratiometric, Current |
| JESD-30 Code |
R-XXSS-T3 |
| Operating Supply Voltage |
15V |
| Number of Channels |
1 |
| Analog IC - Other Type |
ANALOG CIRCUIT |
| Polarization |
Bidirectional |
| Nominal Supply Current |
10mA |
| Output Current |
50mA |
| Max Supply Current |
10mA |
| Accuracy |
±0.5% |
| Response Time |
0.5μs |
| Coil Resistance |
30Ohm |
| Sensor Type |
Hall Effect, Closed Loop |
| Linearity |
0.1 % |
| Max Supply Voltage (DC) |
15V |
| Min Supply Voltage (DC) |
12V |
| For Measuring |
AC/DC |
| Width |
36.5mm |
| REACH SVHC |
No SVHC |
| RoHS Status |
RoHS Compliant |
CSNP661-002 Overview
For safety reasons, the current sensors are packaged in Module, Single Pass Through packages. As a safety measure, the current sensors are packaged inside the Bulk to prevent damage to the devices. It is recommended that current sensors do not supply a current greater than 10mA. Currently, the sensors have 3 terminations. A current sensor is designed for a current of 90A. When operating, the current sensors could deliver a voltage of 15V. Accordingly, the current provided by current sensors should have a nominal value of 10mA. The current output from current sensors should be 50mA. It is important that the voltage supplied by these sensors is not lower than 12V in a DC circuit. Nevertheless, the DC circuit voltage should not exceed 15V when the current sensors are being used.
CSNP661-002 Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -40°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Closed Loop
Supply Voltage: ±12V~15V
Frequency: 150kHz
Module, Single Pass Through Package
CSNP661-002 Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSNP661-002 Current Sensors applications.
- Continuity
- Power supply management
- Closed-L oop DC- and AC-Current Sensor Modules
- AC variabel speed drives and servo motor drives
- Battery supplied applications
- Power factor correction
- Battery chargers and systems
- Uninterruptible Power Supplies(UPS)
- Overcurrent Detection
- Leakage Current Sensors