Parameters |
Factory Lead Time |
4 Weeks |
Mount |
PCB |
Mounting Type |
Through Hole |
Package / Case |
Module, Single Pass Through |
Number of Pins |
3 |
Housing Material |
PBT |
Operating Temperature |
-25°C~85°C |
Packaging |
Bulk |
Published |
1998 |
Series |
CSLA |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Termination |
Connector |
Max Operating Temperature |
85°C |
Min Operating Temperature |
-25°C |
Voltage - Supply |
6V~12V |
Current Rating |
20mA |
Output |
Ratiometric, Voltage |
Current - Supply (Max) |
20mA |
Output Type |
Voltage |
Polarity |
Bidirectional |
Number of Channels |
1 |
Max Supply Voltage |
12V |
Min Supply Voltage |
6V |
Polarization |
Bidirectional |
Nominal Supply Current |
20mA |
Max Supply Current |
20mA |
Max Voltage Rating (DC) |
13.2V |
Response Time |
3μs |
Wire/Cable Diameter |
10.9 mm |
Sensor Type |
Hall Effect, Open Loop |
Sensing Method |
Inductive |
Sensitivity |
32.7mV/N |
Max Supply Voltage (DC) |
13.2V |
Min Supply Voltage (DC) |
5.4V |
For Measuring |
AC/DC |
Current - Sensing |
72A |
Height |
35.56mm |
Length |
34.3mm |
Width |
10.414mm |
REACH SVHC |
Unknown |
RoHS Status |
RoHS Compliant |
Lead Free |
Lead Free |
CSLA2CD Overview
In order to provide safety protection, the current sensors are packaged in Module, Single Pass Through packages. Current sensors are packaged in Bulk in order to avoid damage to the devices. They should be capable of supplying a maximum current of 20mA. A current sensor should not provide a current greater than 20mA. In order for the current sensors to operate, the operating temperature must not be lower than -25°C. Nevertheless, the current sensors should be set to 85°C as the maximum operating temperature. For the current sensors, the current is 20mA. This current sensor contains 3 pins. A current sensor should normally provide a current of 20mA. This sensors should supply a voltage not less than 5.4V in a DC circuit. But the voltage supplied by the current sensors should not exceed 13.2V in the DC circuit.
CSLA2CD Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -25°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 6V~12V
Sensing Current: 72A
Module, Single Pass Through Package
CSLA2CD Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA2CD Current Sensors applications.
- Monitor Motor Operation
- Uninterruptable Power Supllies (UPS)
- Power Supplies for welding applications
- Power factor correction
- Static converters for DC motor drives
- AC variable speed drives
- Uninterruptible Power Supplies(UPS)
- Industrial Monitoring and Control Systems
- Mobile applications
- General purpose inverters